Fisher & Paykel 60 Installation Instructions And User Manual page 12

Freestanding cooker
Table of Contents

Advertisement

Installation instructions
10
After installing the freestanding cooker and connecting the gas supply:
Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a
1
time by brushing the solution over the connection.
The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then
recheck for leaks.
Important!
Do not use a naked flame to test for leaks.
Adjust the test point pressure or supply pressure to the value that is appropriate for the gas
2
type.
Test the operation of the appliance:
3
Turn on the appliance gas controls and light each burner individually and in combination.
Check for a well-defined blue flame without any yellow tipping. If any abnormality is
evident, then check that the burner cap is located properly and the injector nipple is
aligned correctly.
Check the minimum burner setting by quickly rotating the gas control knob from the
maximum to the minimum position. The flame must not go out. If you need to adjust the
setting, see 'Adjusting the minimum burner setting' following.
Important!
This appliance IS NOT SUITABLE for installation with a hose assembly.
Fig. 6 Adjusting the connection pipe
Fig. 7 Gas supply inlets
Plug