Gas supply
The gas connection must be carried out by an authorised person according to the relevant
standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas
inlet pipe, upon which the gasket has been placed (see Fig.s following).
Conical adaptor and gasket are supplied with the appliance (packed with conversion kit for use
with Natural gas or LPG gas).
This appliance is suitable for use with Natural Gas or LPG gas. (Check the "gas type" sticker
attached to the appliance).
For Natural gas models, the gas supply is connected to the pressure regulator which is supplied
with the appliance. Adjust the regulator to obtain a test point pressure of 1 kPa with the two
semi-rapid burners operating at the maximum.
For LPG gas models the gas supply is connected to the test point adaptor which is supplied with
the appliance. Ensure that the supply pressure is regulated to 2.75 kPa.
The connection must be made at the rear of appliance (left or right); the pipe is not to cross the
cooker.
Close off the unused inlet with the cap and sealing gasket supplied (Fig. 7).
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe as shown following.
Gas connection for
LPG GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Test
point
Fig. 4 LPG gas connection
Installation instructions
Gas connection for
NATURAL GAS
Test
point
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Fig. 5 Natural gas connection