Chicago Electric 94191 Assembly And Operation Instructions Manual page 17

Gas engine generator 13 hp
Table of Contents

Advertisement

PluG
(59A)
Engine maintenance:
4.
After first 5 to 8 hours of use:
a.
of use. Change oil every 25 hours of use when operating the Engine under a
heavy load or in high temperatures. To change the oil, remove the Plug (59A)
and allow the old oil to drain in a proper container. Once drained, replace the
Plug. If the Engine will be run in temperatures above 32° Fahrenheit, use SAE
30 weight oil. If the Engine will be run in temperatures below 32° Fahrenheit,
use SAE 5W-30 weight oil. To fill the Engine crankcase with new oil, unscrew
and remove the Oil Dipstick (65A). Pour engine oil into the Dipstick Hole until the
level of oil is even with the top edge of the Dipstick Hole. Make sure to screw the
Oil Dipstick (65A) firmly back into its Dipstick Hole. Also, make sure to dispose
of the old oil according to local waste disposal requirements.
(See figure G.)
SPARK PluG (28A)
SPARK PluG WIRE (36A)
AIR fIlTER SEPARATOR
(20A)
AIR fIlTER cOVER
(18A)
b. After every 25 hours of use: Service the Air Filter Element (19A) and Air Filter
Separator (20A). To do so, remove the Air Filter Cover (18A). Remove the Air
Filter Element. Immerse the Air Filter Element in a mild solvent and squeeze
the Element several times to clean. Remove the Element from the solvent and
for technical questions, please call 1-800-444-3353.
SKU 94191
fIGuRE G
Change oil. Then, change oil every 50 hours
OIl dIPSTIcK
fIGuRE H
AIR fIlTER ElEMENT
(19A)
(65A)
Page 17