RT500 THERMOSTAT DEFAULT SETTINGS
Changes to the default settings should only be made by the Engineer
carrying out the installation or other qualified person.
The installer should select the "jumper"
positions required if changes need to be
made to the factory default settings. The
"jumpers" are found on the rear of the
RT500.
Jumper
Program
Span
1,2,3,4,5
NOTE:
The Reset button must be pressed after changing jumper positions.
RT500BC INSTRUCTION MANUAL
Function
Jumper for 5-2 (factory default setting) or 7
individual days programming.
Movable jumper for selecting temperature span
of ± 0.5°C (factory default setting) or ± 1.0°C
Removable jumpers for altering the RF address
code when used in conjunction with the
teaching mode of the boiler control.