Powerup Test

The Powerup Test procedure uses minimal parameter settings to run
the motor. The procedure describes two alternative methods for
commanding the inverter:
terminals.
Check power input and motor output wiring (see page 3 diagram).
If using logic terminals for testing, verify correct wiring on [PCS],
[FW], [H], [O] and [L] (bottom row) per the diagram on page 3.
Reverse [RV] input wiring (defaults to terminal [2]) is optional.
Step
Description
Set speed command
1
source setting
Set Run FW command
2
source
Set Run REV
3
command source
4
Set motor base freq.
5
Set motor poles
Set keypad display to
6
monitor freq.
Perform safety check
7
Run Forward
8
command
9
Increase speed
10
Decrease speed
11
Stop motor
Run Reverse
12
command (optional)
13
Stop motor
via the inverter keypad, or via the logic
Via Keypad
A001=00
(Keypad pot)
A002=02
(Run key)
H004 = 4 (default), change only if your motor is
different
Access d001, press Func key, display will show 0.0
Disconnect load from motor
Turn keypad pot. To MIN
position
Press Run key
Rotate keypad pot. CW
direction
Rotate keypad pot. CCW
direction
Press stop key
- 6 -
Via Logic
Terminals
A001=01
[H-O-L] input
A002=01
[FW] input
C002=01 (default)
[RV] input
A003=60
Ensure voltage on [O] −
[L] terminals = 0V
Turn ON the [FW]
terminal
Increase voltage at [O]
Decrease voltage at [O]
Turn OFF the [FW]
terminal
Turn ON the [RV]
terminal
Turn OFF the [RV]
terminal