Electrical Data - Heat Controller HP Series Installation, Operation & Maintenance Manual

Residential packaged geothermal heat pump 1 1/2 to 5 tons
Table of Contents

Advertisement

Heat Controller, Inc.
� WARNING! �
WARNING! To avoid possible injury or death
due to electrical shock, open the power
supply disconnect switch and secure it in an
open position during installation.
� CAUTION! �
CAUTION! Use only copper conductors for field
installed electrical wiring. Unit terminals are not
designed to accept other types of conductors.

Electrical Data -

HP
Volt
Rated
Model
Code
Voltage
018
G
208-230/60/1
024
G
208-230/60/1
030
G
208-230/60/1
036
G
208-230/60/1
042
G
208-230/60/1
048
G
208-230/60/1
060
G
208-230/60/1
HACR circuit break in U.S. only
All fuses Class RK-5
HP SerieS
ELECTRICAL - LINE VOLTAGE
Voltage
Min/Max
RLA
LRA
Qty
197/254
7.2
33.0
1
197/254
12.8
58.3
1
197/254
14.1
73.0
1
197/254
16.7
79.0
1
197/254
17.9
112.0
1
197/254
21.8
117.0
1
197/254
26.3
134.0
1
Wire length based on one way measurement with 2% voltage drop
Wire sizes based on 140°F (60°C) copper conductor
Electrical - Line Voltage
All field installed wiring, including electrical ground, must
comply with the National Electrical Code as well as all
applicable local codes. Refer to the unit electrical data for
fuse sizes. Consult wiring diagram for field connections
that must be made by the installing (or electrical)
contractor.
All final electrical connections must be made with a
length of flexible conduit to minimize vibration and sound
transmission to the building.
General Line Voltage Wiring
Be sure the available power is the same voltage and
phase shown on the unit serial plate. Line and low voltage
wiring must be done in accordance with local codes or the
National Electric Code, whichever is applicable.
HWG
Fan
Loop
Total
Pump
Motor
Pump
Unit
Amp
FLA
Amp
FLA
0.4
1.00
4.0
12.6
0.4
1.50
4.0
18.7
0.4
3.00
4.0
21.5
0.4
1.80
4.0
22.9
0.4
3.00
4.0
25.3
0.4
3.40
4.0
29.6
0.4
4.90
4.0
35.6
24
Installation, Operation & Maintenance
Min
Max
Circ
Fuse/
Amp
HACR
14.4
20
21.9
30
25.0
35
27.1
40
29.8
45
35.1
50
42.2
60
21