Field Conversion Of Air Discharge - Heat Controller HP Series Installation, Operation & Maintenance Manual

Residential packaged geothermal heat pump 1 1/2 to 5 tons
Table of Contents

Advertisement

Heat Controller, Inc.
Overview
Horizontal units can be field converted between
side (straight) and back (end) discharge using the
instructions below.
Note: It is not possible to field convert return air
between left or right return models due to the
necessity of refrigeration copper piping changes.
Preparation
It is best to field convert the unit on the ground before
hanging. If the unit is already hung it should be taken
down for the field conversion.
Side to Back Discharge Conversion
1. Place unit in well lit area. Remove the screws as shown
in Figure 4 to free top panel and discharge panel.
2. Lift out the access panel and set aside. Lift and rotate
the discharge panel to the other position as shown,
being careful with the blower wiring.
3. Check blower wire routing and connections for tension
or contact with sheet metal edges. Reroute if necessary.
4. Check refrigerant tubing for contact with
other components.
5. Reinstall top panel and screws noting that the location
for some screws will have changed.
6. Manually spin the fan wheel to insure that the wheel
is not rubbing or obstructed.
7. Replace access panels.
Back to Side Discharge Conversion
If the discharge is changed from back to side, use above
instruction noting that illustrations will be reversed.
Left vs. Right Return
It is not possible to field convert return air between left or
right return models due to the necessity of refrigeration
copper piping changes. However, the conversion process
of side to back or back to side discharge for either right
or left return configuration is the same. In some cases,
it may be possible to rotate the entire unit 180 degrees
if the return air connection needs to be on the opposite
side. Note that rotating the unit will move the piping to the
other end of the unit.
10
HP SerieS

FIELD CONVERSION OF AIR DISCHARGE

Figure 4: Left Return Side to Back
Remove Screws
Water
Connection End
Side Discharge
Water
Connection End
Water
Connection End
Back Discharge
Figure 5: Right Return Side to Back
Return Air
Return Air
Drain
Discharge Air
12
Installation, Operation & Maintenance
Return Air
Rotate
Return Air
Move to Side
Replace Screws
Return Air
Drain
Discharge Air
Supply Duct
Side Discharge
Connection End
Back Discharge
Water
Connection End
Water

Hide quick links: