Electrical Data - Heat Controller HEV Series Installation, Operation & Maintenance Manual

Residential packaged geothermal heat pump 2 to 5 tons
Hide thumbs Also See for HEV Series:
Table of Contents

Advertisement

Installation, Operation & Maintenance
WARNING!
WARNING! To avoid possible injury or death
due to electrical shock, open the power
supply disconnect switch and secure it in an
open position during installation.
CAUTION!
CAUTION! Use only copper conductors for field
installed electrical wiring. Unit terminals are not
designed to accept other types of conductors.

Electrical Data -

HE
Volt
Rated Voltage
Model
Code
024
1
208-230/60/1
030
1
208-230/60/1
036
1
208-230/60/1
042
1
208-230/60/1
048
1
208-230/60/1
060
1
208-230/60/1
HACR circuit break in U.S. only
All fuses Class RK-5
HEV/H SERIES
ELECTRICAL - LINE VOLTAGE
Compressor
Voltage
Model
Min/Max
RLA
LRA
197/254
024
11.7
58.3
197/254
030
14.7
73.0
197/254
036
18.0
83.0
197/254
042
21.8
96.0
197/254
048
25.0
104.0
197/254
060
28.9
152.9
Wire length based on one way measurement with 2% voltage drop
Wire sizes based on 140°F (60°C) copper conductor
Electrical - Line Voltage
All field installed wiring, including electrical ground, must
comply with the National Electrical Code as well as all
applicable local codes. Refer to the unit electrical data for
fuse sizes. Consult wiring diagram for field connections
that must be made by the installing (or electrical)
contractor.
All final electrical connections must be made with a
length of flexible conduit to minimize vibration and sound
transmission to the building.
General Line Voltage Wiring
Be sure the available power is the same voltage and
phase shown on the unit serial plate. Line and low voltage
wiring must be done in accordance with local codes or the
National Electric Code, whichever is applicable.
Int
HWG
Fan
Loop
Pump
Motor
Pump
FLA
FLA
Qty
FLA
1
0.4
1.7
3.9
1
0.4
1.7
3.9
1
0.4
1.7
3.9
1
0.4
1.7
5.2
1
0.4
1.7
5.2
1
0.4
1.7
6.9
22
Heat Controller, Inc.
Total
Min
Max
Unit
Circuit
Fuse/
Fuse/
FLA
Amps
HACR
HACR
17.7
20.6
32.3
20.7
24.3
39.0
23.9
28.4
46.3
29.1
34.5
56.3
32.2
38.5
63.5
37.9
45.1
74.0
Max
30
35
45
50
60
70