Service Manual
Appendix 5:
Spec.
Model
Compressor
Outdoor fan motor
Model
Indoor fan motor
Model
Indoor fan motor
1.
Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Blue - Red
VMH SerieS
1x2
DA130S1C-20FZ
YDK70-6FB
9k Mini-Split
RPG20B
/
/
DA130S1C-20FZ
0.95Ω(20℃)
Outdoor unit
1x3
DA150S1C-20FZ
YDK70-6FB
Indoor unit
12k Mini-Split
RPG20B
12k Cassette
YDK45-6B
Resistance Value
DA150S1C-20FZ
0.95Ω(20℃)
48
Heat Controller, Inc.
1x4
TNB306FPGMC-L
YDK180-8GB
18k Mini-Split
RPG28H
18k Cassette
YDK45-6B
TNB306FPGMC-L
0.53Ω(20℃)