HEAT CONTROLLER, INC. Wall Mounted Mini-Split System Inverter Single-Zone Air Conditioning Service Manual AS-Q1835JZ0 [VMC18SB-1] AS-Q2435JZ0 [VMC24SB-1] Before servicing the unit, read the “safety precautions” in this manual. Only for authorized service personnel.
2. Piping Diagrams Indoor Unit Outdoor Unit Liquid Side 2-Way Valve Heat Heat Exchanger Exchanger (Evaporator) (Condenser) Accumulator Gas Side 3-Way Valve Compressor Refrigerant Flow LOC. Description PCB Connector Thermistor for indoor air temperature CN_TH1(INDOOR) CN_TH2(INDOOR) Thermistor for evaporating temperature CN_TH3(INDOOR) Thermistor for outdoor air temperature CN_TH2(OUTDOOR)
4. Exploded View Indoor Unit 135316 152301 135314 733010 131410 149304 342800 359011 135311 354210 346810 35211B 268711A 135516 147581 352150 146811 Indoor Air, Evaporator Thermistor 263230 249951 267110 268711B Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC.
Page 7
Outdoor Unit 18k Outdoor Air, Condenser 554031 Thermistor 437212 263230B 661400 435512 EEV Coil 552113 649950 349600 W0CZZ 268711F 435511 559010 546810 567480E S-pipe, D-pipe Thermistor 430960A 437211 Discharge Suction 261704 447910 550140 554160 552203A 435301 552203B 349480 437210 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC.
Page 9
Specifications and performance data subject to change without notice. HEAT CONTROLLER, INC. 1900 WELLWORTH AVENUE • JACKSON, MICHIGAN 49203 THE QUALITY LEADER IN CONDITIONING AIR P/No.:MFL42286413...