TROUBLE-
SHOOTING
,/k WARNING
Unplug chain saw from power source before servicing. Severe
injury or death could occur from electrical shock or body contact
with moving chain.
OBSERVED
POSSIBLE
FAULT
CAUSE
REMEDY
Saw runs, but does
Chain asserabled backwards
See Assembly,
page 8
_ot cut.
on guide bar
Saw does not cut
Chain is dull
See Sharpening your
unless heavily
Saw Chain, page 2 I
forced. Cutting
(non-Fast Sharp model) or
produces only
page 24 (Fast Sharp
sawdust with few
model)
large chips.
2
Saw runs Slow.
Low power supply voltage
Extension cord wire size too
Saw stalls easily,
small. See ExterLfion
Cords, page 12
Motor of saw does
Switch lockout not pressed in
Press in switch lockout
not run when you
m release trigger
before squeezing trigger
squeeze_gger.
Extension cord connections
loose
Open line fuse or circuit
breaker
Bad motor brushes
Open wiring circuit on saw
Check cord connections
Check line fuse or circuit
breaker
See authorized service center
(see page 29)
See authorized service center
(see page 29)
Motor of saw runs,
but chaindoesnot
move.
Gear train failure
See authorized
service center
(see page 29)
Chain does not get
oil.
Clogged oil slot in guide bar
Oil is too thick
Remove guide bar and clean
oil slot
Use correct weight of oil.
See Filling Oil Tank,
page 11
Chain comes off
Chain is loose
Tighten chain. See Saw
guide bar.
Chain Ter_ion
Adju_tmem,
page 10
Guide bar and chain not
Se_ Assembly,
page g
assembled right
Saw smokes.
Saw damaged. Do not use saw.
See authorized service center
(see page 29)
Saw leaks oil.
Oil cap is not secure.
Tighten oil cap.
Note: Empty oil tank
when not in use.

Hide quick links: