Roof
Mount
WARNING:
To avoid the risk of property
damage,
personal
injury,
or death,
it is the
installer's
responsibility
to ensure that
whatever means are used to move or lift
the unit are safe and adequate:
Keep the unit in an upright position at
all times.
The method of mounting should be designed
so as not to overload roof structures or transmit
noise to the interior of the structure. Refrigerant
and electrical
lines should be routed through
suitably waterproofed
openings to prevent water
leaking into the structure.
CONNECTING
REFRIGERANT
TUBING
BETWEEN THE INDOOR & OUTDOOR
UNiT
This system
uses R-410A
refrigerant
with POE oil. When servicing,
cover or
seal openings to minimize
the exposure
of the refrigerant system to air to prevent
accumulation
of moisture
and other
contaminants.
General Information
After outdoor and indoor unit placement has been
determined,
route refrigerant tubing between the
equipment in accordance with sound installation
practices.
,
When connecting refrigerant linesets together,
it is recommended
that dry nitrogen be flowing
through
the joints during brazing. This will
prevent internal oxidation and scaling from
occurring.
,
Refrigerant
tubing
should
be routed
in a
manner that minimizes
the length of tubing
and the number of bends in the tubing.
,
Refrigerant
tubing should
be supported
in
a manner that the tubing will not vibrate or
abrade during system operation.
,
Tubing should be kept clean of foreign debris
during installation.
,
Every effort should be made by the installer
to ensure that the field installed refrigerant
containing
components
of the system have
been
installed
in accordance
with these
instructions and sound installation practices to
insure reliable system operation and longevity.
,
The maximum recommended interconnecting
refrigerant line length is 75 feet, and the vertical
elevation difference
between the indoor and
outdoor sections should not exceed 20 feet.
,
If precise
forming
of refrigerant
lines
is required,
a copper
tubing
bender
is
recom mended. Avoid sharp bends and contact
of the refrigerant lines with metal surfaces.
Filter Drier Installation
A filter dryer is provided with the unit and must
be installed in the liquid line of the system. If the
installation
replaces a system with a filter dryer
already present in the liquid line, the filter dryer
must be replaced with the one supplied with the
unit. The filter dryer must be installed in strict
accordance
with the manufacturer's
installation
instructions.
Optional Equipment
Optional equipment such as liquid line solenoid
valves, twinning kit, low ambient,
etc., should
be installed
in strict
accordance
with
the
manufacturer's
installation
instructions.
ELECTRICAL
CONNECTIONS
WARNING:
Shut off all electrical
power to the unit
before
performing
any maintenance
or
service on the system.
Failure to comply
may result in personal injury or death.
Pre-Electrical
Checklist
_ Verify that the voltage, frequency and phase
of the supply source are the same as those
specified on the unit rating plate.
_ Verify that the service provided by the utility is
sufficient to handle the additional load imposed
by this equipment.
4 For minimum circuit ampacity and maximum
overcurrent
protection, see unit rating plate.
Wiring
Diagram / Schematic
A wiring diagram/schematic
is located on the
inside cover of the electrical
box of the outdoor
unit. The installer should become familiar with
the wiring
diagram/schematic
before
making
any electrical connections
to the outdoor unit.
Line Voltage
,
Electrical power wiring must comply with the
current provisions
of the NEC (ANSl/NFPA
70) and with applicable
local codes having
jurisdiction.
,
Providepowersupplyforthe
unit in accordance
with the unit wiring diagram, and the unit rating
plate.