Available languages

Performance Data Sheet
Hotpoint SmartWater Filtration System
HWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
'100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic
Effects
Parameter
Chlorine
T&O
Particulate**
Parameter
USEPA
MCL
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Awazine
2,4-D
Asbestos
Influent
Challenge
1.9 ppm
200,000
Effluent
Average
Maximum
0.02 ppm
0.05 ppm
3,978
7,800
% Reduction
Average
Minimum
98.90%
97.37%
98.00%
96.10%
USEPA
MCL
1 NTU***
99.95%
Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard No. 53: Health Effects
Influent
Effluent
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFL/ml
Maxinlllln
0.1 NTU
55
1 ppb
4.3 ppb
0.00005
ppm
0.003 ppm
0.090 ppm
1.2 MFL/ml
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFL/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
* Testedusing a flow rate of 0.5 gpm; pressure of 120psig; pH of Z5-+0,5; t emp. of 20-+2.5 C
** Measurement #7partioles/ml
*** NTU = Nephelometrio Units
% Reduction
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
_ Capacity: certified for up to 300 gallons (1135 1); tip to six months
for models without
a replacement
filter indicator
light;
tip to one year for models with a replacement
filter indicator
light
_/_Pressure requirement:
40-120 psi (2.8-8.2 bar), non-shock
NTemperature:
33-100 F (0.6-38 C)
_Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance
Requirements
N/Flush new cartridge
at full 1low 1or 3 minutes
to purge out trapped
ain
_ Replace cartridge
when flow becomes
too slow.
Special Notices
_/Installation
instructions;
parts and service availability; and standard
warranty are included with the product when shipped.
_This
drinking
,a-ater system must be maintained
according
to manufacturer's
instructions,
including
replacement
of
filter cartridges.
_Do
not use with water that is microbiologically
unsafe or of unknown
quality without adequate
disinfection
before or
after the system. Systems certified 1or cyst reduction
may be used on disinfected
water that may contain
filterable
cysts.
NThe contaminants
or other substances removed or reduced by this water treatment
system are not necessarily in ),our water.
_ Check 1or compliance
with the state and local laws and regulations.
System
'Ik'sted
and
Certified
by NSF international
against
ANSI/NSF
Standard
42 & 53 for the
reduction
of:
Stamdard
No. 42: Aesthetic
Effects
Chemical
Unit
'l_,_ste and
Odor
Reduction
Chlorine
Reduction,
(;lass
i
Mechanical
Filtration
Unit
Particulate
Reduction,
Class
I
Standard
No.
53: Health
Effects
Chemical
Reduction
Unit
Lead and
Atrazine
Reduction
Lindane
and 2,4-D Reduction
Mechanical
Filtration
Unit
Turbidity
Reduction
Cyst and
Asbestos
Reduction
Manutactured
for: General
Electric
Company,
Louisville,
KY 40225
2 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents