Hotpoint HS2321L Service Information

Hotpoint HS2321L Service Information

Built in integrated larder fridges

Advertisement

Service
Information
© 2012 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Indesit Company UK Ltd
5407691
Issue 1
SM003482 ~ C00291854
Built In
Integrated
Larder
Fridges
Models
Covered
HS2321L
HS2322L
Dec. 2012
Comm.
Code
54085
77819

Advertisement

Table of Contents
loading

Summary of Contents for Hotpoint HS2321L

  • Page 1 5407691 Issue 1 Dec. 2012 SM003482 ~ C00291854 Built In Integrated Larder Fridges Models Comm. Covered Code HS2321L 54085 HS2322L 77819 Service Information Indesit Company UK Ltd © 2012 Reg. Office: Peterborough PE2 9JB Registered in London: 106725...
  • Page 2 Indesit Company HEALTH AND SAFETY For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published. Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
  • Page 3 Indesit Company HEALTH AND SAFETY 19. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system. 20. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a). 21.
  • Page 4: Table Of Contents

    2 litre bottle and one removable door shelf for bottles. The HS2321L model is an over counter 216 litre larder fridge and is manufactured in Italy. The product was launched November 2008.
  • Page 5: Introduction

    Total Capacity Gross: 216 litres Net: 213 litres Defrosting Automatic Climate Class HS2321L - N/ST (+16°C to +38°C) HS2322L - SN/N/ST/T (+10°C to +43°C) Energy Consumption HS2321L - to 1998 Regulations 161 kWh / year 0.44 kWh / 24 hours...
  • Page 6: Overall View

    Indesit Company OVERALL VIEW - refer to illustration below Light Interior Lamp switch & Cover Control Panel Service Manual UK English 6 of 17...
  • Page 7: Autotest Mode

    Indesit Company AUTOTEST MODE Autotest Function: Shown pushed in Light switch button 1 - Super Cool LED 2 - Temp LED’s 3 - Selector Button To start Autotest: With the Fridge Door open, push and hold in the Light switch button (light Off position). See item 4 above.
  • Page 8: Replacement Door Seals For Door Assemblies

    Indesit Company REPLACEMENT DOOR SEALS FOR DOOR ASSEMBLIES Various types of door seal are supplied as replacements. See Figs. A, B and C showing seal profiles. Note also the liner profiles A5, A6 and B5, B6 below. The door seal, Fig. A, is retained by the liner which has 2 screws securing each corner. The door seal as illustrated in Fig.
  • Page 9: Replacing The Light Bulb

    Indesit Company Replacing the Light Bulb To replace the light bulb in the refrigerator compartment, 1. Pull out the mains plug from the electrical socket. 2. Access the light bulb by removing the cover as indicated in the diagram below. 3.
  • Page 10: Module And Wiring Diagram

    AC: Alternating current LF: Refrigerator light MV: Motor fan CO: Compressor PT: PTC relay RH: Circuit breaker PR: Refrigerator light button/ magnetic reed switch Probe Start condenser (where installed) LZ: Freezer light RC: FZ frame resistor (where installed) HS2321L HS2322L...
  • Page 11 Indesit Company PROGRAMMING (Using EMIT) This machine can be programmed via the Emit, using a USB lead (Part number C00222800), Hardware key (Part number C00115587) and the Memwriter software. Other types of Cable are available Black Serial Hardware Key USB - Serial Cable Replacement pins for the Serial Hardware Key are available as Part No.
  • Page 12 Indesit Company MAIN BOARD PROGRAMMING NOTE: The module does not have a physically replaceable EEProm. Smart Card Programming a Main Board Reader There are a number of ways the board can be programmed - some of which are not applicable to certain markets. Types of programming: Handheld Terminal (Not UK) Emit / Memwriter (UK Indesit...
  • Page 13 SMARTCARD PROGRAMMING PROCEDURE - FLOWCHART START DISCONNECT THE SMARTCARD READER FROM THE DISCONNECT (unplug) THE APPLIANCE FROM THE ELECTRICAL SUPPLY (grid) APPLIANCE AND THE SMARTCARD FROM THE SMARTCARD READER AND ACTION BELOW: LED was flashing SLOWLY, and a If the INSERT A VALID SMARTCARD, RELATING TO THE MODEL &...
  • Page 14 Indesit Company CONNECTING THE LOW END ADAPTOR - 2007 Version with single and twin cable IMPORTANT: 1. ALWAYS unplug the appliance from the mains electricity supply when connecting or disconnecting wiring on the module. 2. ALWAYS connect the smart card reader or Hardware Key to the Low End Adaptor BEFORE connecting the adaptor to the module PCB connection L4.
  • Page 15: Programming (Emit)

    Indesit Company Module Light Sequences - shown for illustrative purposes only Unprogrammed Module - with power applied Temperature select button Unprogrammed modules will have all 5 lights illuminated. Note: Service Modules are supplied blank and will require programming. See Programme. Low End Adaptor Connection point L4 Module - Programmed...
  • Page 16 Indesit Company INSTALLATION & DOOR REVERSAL KUP 100 KM 160 - KUP 141 KM 190 1018 1022 1225 KM 230 - KUP 200 1220-1224 ATTENZIONE WARNING ATTENTION 08/2009 - 195021555.07 Service Manual UK English 16 of 17...
  • Page 17 Indesit Company Service Manual UK English 17 of 17...