Electrical Connection
We recommend
that you have the
electrical hookup of your range done
by a qualified electrician°
Have the
electrician
show you where your
range disconnect
is located.
Call your Electric Company
and ask
which codes apply in your area. If
there are no codes, you must follow
the NATIONAL
ELECTRICAL
CODE, ANSI/NFPA
NO. 70-1987.
You can get a copy by writing:
National
Fire Protection
Association
Batterymarch
Park
Quincy, MA 02269
If you fail to wire your range in
accordance
with gover_ting codes,
you may create a hazardous
condition.
You must use a three-wire,
single-
phase AC 120/240 Volt or 208Y/120
Volt, 60 Hertz electrical
system to
operate your range.
Use #8 wire and 40 Amp fuse or
circuit breaker for 120/240 Volt and
208/120 Volt systems°
Do not use aluminum
wiring to
connect your range to the
household
circuit.
To Make Electrical
Connection:
1. Remove the junction block
access cover (on range back).
2. Use a 3-wire flexible cord (must
be rated for 40 Amps--1251250
Volts, with closed loop terminals
and approved
for use with
household
electrical
ranges) or a
4-wire flexible cord (required
for
mobile homes or where local codes
do not allow grounding
through the
neutral),
You must use a clamp or strain
relief to hold the cord or conduit.
ThreeWtre Cord
Connection
1. Remove the top nuts on the
junction
block studs.
2, Tighten the back nuts°
3. Install the three wire cord and
the strain relief in the hole in the
strain relief bracket
4. Connect the red and black leads
to the outer terminals
and the white
lead to the center terminal.
5. Push the cord upward (to relieve
strain), while tightening
the strain
retief clamp.
TopNut
/
/
t/
/
Strain
ReliefClamp
If local codes require an
ungrounded
neutral:
a. Remove ground strap.
b. Fasten the white wire to the
center terminal.
c. Use the screw from the
ground strap to fasten a #10
copper wire to the range. Secure
the other end of the wire to a
grounded
cold water pipe or use
another approved grounding
method,
Four Wire Cord
Connection
1, Remove the top nuts on the
junction
block studs.
2. Tighten the back nuts_
3. Remove the ground screw, then
remove the ground strap_
4. Install the four wire cord and
strain relief in the hole in the strain
retief bracket.
5. Connect the red and black lead
to the outside terminals
and the
white lead to the center terminal.
6. Attach the green lead below the
junction
block with the ground
screw that was removed earlier
(step3).
7, Push the strain relief upward (to
relieve strain), while tightening
the
strain relief clamp,
1
Ground
Washer
Ground
Screw
/
/
/
/
Strain
Relief Clamp
31