CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip-
ing and connections
for leaks
after installing or servicing. Cor-
rect all leaks at once.
_.
WARNING: Never use an open
flame to check for a leak. Apply a
mixture of liquid soap and water
toe, joints. Bubbles formingshow
a leak. Correct all leaks at once.
Pressure
Testing
Gas Supply
Piping
System
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect
heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.
2.
Cap off open end of gas pipe where
manual shutoff valve was connected.
3.
Pressurize supply piping system by ei-
ther using compressed air or opening
gas valve located on or near gas meter.
4.
Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
5.
Correct all leaks at once.
6.
Reconnect heater and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG
1. Close manual shutoff valve (see Fig-
ure 14).
2.
Pressurize supply piping system by ei-
ther using compressed air or opening
gas valve on or near gas meter.
3.
Check all joints from gas meter to
manual shutoff valve (see Figure 15).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.
4.
Correct all leaks at once.
Pressure
Testing
Heater Gas
5.
Connections
6.
1.
Open manual shutoff valve (see Fig-
ure 14).
2.
Open maingasvalvelocated onor near
gas meter.
3.
Make sure control knob of heater is in
7.
the OFF position.
4.
Check all joints from manual shutoff
valve to thermostat gas valve (thermo-
stat-controlled models) or control valve
(variably-controlled
models) (see Fig-
ure 15). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
Manual
Shutoff Valv_:_pen:
Ir------r
I
Closed
Figure 14 - Manual Shutoff Valve
Manual
Shutoff
_...... Valve
;3_v
Figure 15 - Checking Gas Joints
Correct all leaks at once.
Light heater (see Operating Heater,
pages 14 and 15 [Thermostat-Con-
trolled Models] or pages 15 and I6
[Variable Manually-Controlled
Mod-
els]). Check all other internal joints for
leaks.
Turn off heater (see To Turn Off Gas to
Appliance,
page 15 [Thermostat-Con-
trolled
Models]
or page
16 ]Variable
Manually-Controlled
Models]).
ThermostatGas Valve or
ControlValve Location
12
io,._t4