Installing Heater Base Assembly - Desa CGG3324N Owner's Operation And Installation Manual

Unvented (vent.free) natural gas log heater
Table of Contents

Advertisement

UNVENTED
NATURAL
GAS
LOG
HEATER
INSTALLATION
Continued
INSTALLING
DAMPER
CLAMPACCESSORYFOR
VENTED
OPERATION
Note: When used as a vented beater, appli-
ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible
material.
If your heater is a manually controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.
1.
The fireplace
does
not meet
the
clearance to combustibles requirements
for vent-free operation.
2.
State or local codes do not permit vent-
free operation.
3.
You prefer vented operation.
If reasons number I or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories. page
22). This will insure vented operation (see
Figure 10). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.
Chimney
Minimum Permanent
Height (ft.)
Flue Opening (sq. in.)
6' to 15'
39 sq. inches
15' to 30'
29 sq.inches
Area of Various
Standard
Round
Flues
Diameter (in.)
Area (sq. in.)
5"
20 sq. inches
6"
29 sq. inches
7"
39 sq. inches
8"
51 sq. inches
Damper __
Clamp
Damper
Damper
Masonry Fireplace
Damper....
Clamp
__
Manufactured
Fireplace
Figure 10 - Attaching Damper Clamp
INSTALLING HEATER BASE
ASSEMBLY
CAUTION: Do not remove the
metal data plates attached to the
heater base assembly.
The data
plates contain Important warranty
information.
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls.
Moving heater
may cause s ges leak.
_k
WARNING: If installing in a
sunken fireplace, special care Is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate eir flow and guard
against sooting. Raise fireplace
floor with noncombustible
mate-
rial. Make sure materiel Is secure.
,_k CAUTION:
Do not pick up
heater base assembly
by burn-
ers. This could damage heater.
Only handle base assembly by
grates.
IMPORTANT:
Make sure the heater burn-
ers are level. If heater is not level, heater will
not work properly. For thermostat models,
avoid damage to thermostat bulb. Avoid
nicks or sharp bends in thermostat bulb
wire. Keep thermostat bulb in mounting
bracket.
Installation
Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided)
(if allowed by local codes)
• sealant (resistant to propane/LP gas, not
provided)
• electric drill with 3/16" masonry drill bit
1.
Apply pipe joint sealant lightly to male
threads of gas connector. Install into
regulator. Connect approved flexible
gas hose to gas regulator of heater (see
Figure 11, page 11).
IMPORTANT: Hold gas regulator with
wrench when connecting gas fittings.
2.
Position heater base assembly in fire-
place.
3.
Mark screw locations through holes in
front of base. If installing in a brick-
bottom fireplace, mark screw locations
in mortar joint of bricks.
10