UNVENTED
NATURAL
GAS
LOG
HEATER
AIR FOR
COMBUSTION
AND
VENTILATION
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions
are provided
for adequate combustion and yen-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today's homes are built more energy efficient
than ever. New materials, increased insula-
tion, and new construction methods help re-
duce heat loss in homes. Home owners weather
strip and caulk around windows and doors to
keep the cold air out and the warm air in.
During heating months, home owners want
their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.
PROVIDING
ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-
tion 5.3, Airfor Comb astion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1.
Unusually Tight Construction
2.
Unconfined Space
3.
Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequa_ ventilation.
Unusually
Tight Construction
The air that leaks around doors and win-
dows may provide enough fresh air for
combustion
and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction
is de-
fined as construction
where:
a.
walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6x10"
kg
per pa-sec-m 2) or less with open-
ings gasketed or sealed and
b.
weather
stripping
has
been
added on openable windows and
doors an____d
C.
caulking or sealants are applied
to areas such as joints around
window
and door frames,
be-
tween sole plates and floors, be-
tween
wall-ceiling
joints,
be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and st other openings.
If your home meats all of the three
criteria above, you must provide ad-
ditional fresh air. See Ventilation Air
From Outdoors, page 6.
If your home does not meat all of the
three criteria above, proceed to De-
termining Fresh-Air Flow For Heater
Location, page 5.
Confined
and Unconfined
Space
The National
Fuel Gas Code (ANS Z223.1,
1992 Section
5.3) defines a confined
space
as a space whose
volume
is less than 50
cubic feet per 1,000 Btu per hour (4.8 m_ per
kw) of the aggregate
input rating
of all
appliances
installed
in that space and an
unconfining
space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m 3 per kw) of the aggregate
input rating of all appliances
installed in that
space. Rooms communicating
directly
with
the space in which
the appliances
are in-
stalled*,
through
openings
not furnished
with
doors,
are considered
a part of the
unconfined
space.
This heater shall not be installed in a con-
fined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining
rooms are communicating
only
if there are doorless passageways
or ventila-
tion grills between
them.