Inspecting Burners - Desa CGG3324N Owner's Operation And Installation Manual

Unvented (vent.free) natural gas log heater
Table of Contents

Advertisement

UNVENTED
NATURAL
GAS
LOG
HEATER
OPERATING
HEATER
Continued
4.
Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation, page 15. If you don't smell
gas, go to the next step.
5.
Press in control knob and turn coun-
terclockwise
_
to the PILOT
position. Keep control knob pressed
in for five (5) seconds (see Figure 22,
page 15).
• Ifrontrol knob decs not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
You may be running
this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
6.
With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note" If pilot does not light, contact
a qualified service person or gas sup-
plier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light.
ing Procedure, column 3.
7.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note: If pilot goes out, repeat steps
3 through 7, pages 15 and 16.
8.
Push in and turn control knob coun-
terclockwise
_
to the HIGH
position. Both burners should light.
Set control knob to desired setting.
Ignitor Electrode
Pilot Burner
l
VARIABLE
CONTROL
OPERATION
l
The variable control valve can be set to
any heat setting and flame height desired
between high and low by simply turning
the control knob until that setting is at-
tained. Even the lowest setting provides
realistic flames and glowing embers from
two burners. Selecting higher settings pro-
duces greater heat output. This results in
increased heating comfort.
A
WARNING:
Do not operate
heater between pilot and high.
CAUTION: Do not try to adjust
heating
levels
by using
the
manual shutoff valve.
II
Shutting
Off Heater
1.
Press in and turn control knob clock-
wise _
to the HIGH position.
2.
Turn the control knob clockwise
to the PILOT position.
3.
Press in control knob and tam clock-
wise _
to the OFF Position.
Shutting
Off Burners
Only (pilot
stays lit)
1.
Turn the control knob clockwise
to the HIGH position.
2.
Pressin and turn controlknob clock-
wise _
to the pilot position.
MANUAL
LIGHTING
PROCEDURE
1
1.
Follow steps 1 through 5 under Light-
ing Instructions, pages 15 and 16.
2.
Depress control knob and light pilot
with match.
3.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, column 1.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns
often.
PILOT FLAME PA'I-I'ERN
Figure 24 show s a correct pilot flame pattern.
Figure 25 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple
to cool. When the thermo-
couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 25
turn heater off (see To Turn Off Gas to
Appliance [Thermostat-Controlled Mod-
els] page 15 or [Variable Manually-Con-
trolled Models] page 16)
see Troubleshooting, pages 18 through 20
Thermocouple
Pilot Burner
Figure 24 - Correct Pilot Flume Pattern
Pilot Burner
Figure 25 - Incorrect Pilot Flame Pattern
Figure 23 - Pilot
16