ROTATED FIELD
The printers can rotate each print field in 90
this command.
<ESC>% - The field rotates, but the base reference point for the field remains the same.
<ESC>R - The field and the base reference point rotate.
The following data stream will rotate the print field but will not change the base reference point of the field:
<ESC>A<ESC>%1<ESC>V800<ESC>H200<ESC>L0202<ESC>WB1E<ESC>Q1<ESC>Z
The following data stream will rotate both the field and the base reference point for that field:
<ESC>A<ESC>R<ESC>%1<ESC>V800<ESC>H200<ESC>L0202<ESC>WB1E<ESC>Q1<ESC>Z
Base
H=200
Ref
Point
V=800
%1
"
COMMAD DEFAULT SETTINGS
There are some types of commands that must have a value specified before a label can be printed. If the data
stream does not contain these commands, a "default" value is assumed. The commands and the default values
are:
o
increments using the Rotate command. There are two variations of
Base
Ref
Point
Label
Feed
Direction
New
Base
Ref
"
Point
V=200
R"
"
8
H=100