1
The printer does not work normally after turned on.
•
Turn off the printer, wait a few seconds, then turn it on again.
•
Is
•
No
Is the AC cable connected correctly?
No
Connect the AC cable correctly.
•
Yes Is +5V supplied to the PANEL connector pins on the PU board (K73 PWB)?
+5V: Pin 5
Yes Is the operator panel cable connected correctly?
No
Yes Replace the operator panel cable. Recovered?
No
Yes End
•
No
Is +5V supplied on the POWER connector of the engine board (K73 PWB)?
Pin 11,12, 13, 14: +5V Pin 3, 4, 5, 6, 23, 24, 25, 26, 27, 28, 29, 30: 0V
No
Check the connection of the POWER connector, or replace the low-voltage power
supply unit.
•
Yes Replace the engine board.
•
Yes
Are the following voltages supplied to the PU connector of the main board?
Pin 137-147, 187-197: +5V
Pin 148, 198: +12V
Yes Is the main board assy inserted correctly?
No
Yes Replace the main board.
•
No
Are the following voltages supplied on the POWER connector of the engine board?
Pin 11, 12, 13, 14: +5V
Pin 1: +12V
Pin 3, 4, 5, 6, 25, 26, 27, 28: 0V
Yes Replace the engine board.
•
No
Replace the low-voltage power supply unit.
41388601TH Rev.2
displayed on the LCD (for about 1 second)?
0V: Pin 2
Connect the cable correctly.
Replace the cover assembly of the operator panel.
Pin 125-136, 175-186: +3.3V
Pin 101-124, 149-174, 199, 200: 0V
Insert it correctly.
Pin 15, 16, 17, 18: +3.3V
Pin 2: -12V
Pin 7, 8, 9, 10: +32V