HP Surestore 6164 - Switch User Manual page 32

Fabric watch
Hide thumbs Also See for Surestore 6164 - Switch:
Table of Contents

Advertisement

Operands
Example
See Also
32
None
To display and modify the Fabric Watch configuration and status:
sw:admin> fwConfigure
1 : Environment class
2 : GBIC class
3 : Port class
4 : Fabric class
5 : E-Port class
6 : F/FL Port (Copper) class
7 : F/FL Port (Optical) class
8 : quit
Select a class => : (1..8) [8] 1
1 : Temperature
2 : Fan
3 : Power Supply
4 : return to previous page
Select an area => : (1..4) [4] 1
Index
ThresholdName
LastEvent
LastEventTime
LastState
=============================================================
1
envTemp001
started
2
envTemp002
started
3
envTemp003
started
4
envTemp004
started
5
envTemp005
started
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5]
fwClassInit
fwConfigReload
fwShow
enabled
10:28:59 on 02/01/2000
enabled
10:28:59 on 02/01/2000
enabled
10:28:59 on 02/01/2000
enabled
10:28:59 on 02/01/2000
enabled
10:28:59 on 02/01/2000
Status
CurVal
LastVal
33 C
0 C
Informative
34 C
0 C
Informative
36 C
0 C
Informative
35 C
0 C
Informative
36 C
0 C
Informative