Threshold Values; Threshold Area Values - HP Surestore 6164 - Switch User Manual

Fabric watch
Hide thumbs Also See for Surestore 6164 - Switch:
Table of Contents

Advertisement

Threshold Values

Threshold Area Values

Using Fabric Watch
Threshold values apply to the specific threshold. Their values are not stored
in the configuration file, and return to the default values if the switch is
rebooted. The following threshold values can be modified:
• Status
Can be enabled or disabled. Enabled by default.
• Behavior type
Allows setting of the event policy to triggered or continuous. Set to
triggered by default.
• Behavior interval
The interval between the same type of alarm. Applies only to continuous
events. The default interval is one second.
Threshold area values include boundaries and alarms, and apply to all
thresholds within an area. Changes are stored in the configuration file.
Boundaries
The following boundary information can be modified:
• Unit string
Represents unit value. Only the default unit strings are supported by
Fabric Watch.
• Time base
Time period within which a specified event is measured. Can be from
one second to one day. Shorter time periods are more sensitive to
fluctuations and therefore provide more detailed information.
• Low boundary
Minimum value. An event is generated if the element value falls below
this boundary.
25