Continuous Events

Using Fabric Watch
• Exceeded
Counter is below the lower boundary or above the upper boundary.
Accompanies a below or above event.
• Changed
Counter value has changed.
• In-between
Counter falls below the upper boundary minus buffer, or rises above the
lower boundary plus buffer. Must be preceded by an above or below
event. If the buffer is set to zero, this event is suppressed.
A continuous event results in an event at each time interval from when the
boundary is initially exceeded until the threshold value has returned within
the boundaries. For example, if port utilization is above the upper
boundary, a new event is generated at each behavior interval until
utilization falls below the upper boundary. The following events can be
generated as continuous events:
• Started
No alarm is generated.
• Below
Counter is below the lower boundary.
• Above
Counter is above the upper boundary.
• Exceeded
Counter is below the lower boundary or above the upper boundary.
Accompanies a below or above event.
• Changed
Counter has changed.
23