Figure 51 Status showing multiple disk failure
The device operating system is not stored on any of the disks, so the HP D2D Backup System is still
usable after replacing the failed disks. Use the Web Management Interface or the System Console
to help you identify the disks that have failed.
Figure 52 RAID showing three disk failures

Replacing the disks

Power off and replace the disks, as described earlier in this chapter. When you power on again,
the RAID will not rebuild automatically. The Summary page continues to show the RAID System as
catastrophically failed. If you look at the Devices or Cartridges page, no information is available other
than that the library is awaiting RAID initialization.
Figure 53 Devices page awaiting RAID initialization
If you have the System Console connected you will see Fault conditions for System Status and RAID Status
and that the RAID is not mounted, even though the disks are shown as OK.