The Remote Control Will Not Work; Cannot End (After The [Power] Button Has Been Pressed) - Epson EMP EMP-7700 Owner's Manual

Epson owner manual projector emp-7700
Table of Contents

Advertisement

The remote control will not work

Power
Freeze
A/V Mute
R/C ON
E-Zoom
OFF
3
Enter
Esc

Cannot end (after the [Power] button has been pressed)

OFF
Point
If an abnormality remains after checking the results of the above inspections, disconnect
the Power Plug from the socket and consult with your dealer.
82 - When the Indicators Provide No Help
G
Is the [R/C ON OFF] switch on the remote control on?
see page 41
G
Is the remote control being aimed in the correct direction?
The operable range of the remote control unit is 30° to the left and
right, and 15° up and down.
see page 21
G
Is the distance between the remote control and the projector too
great?
The operable distance of the remote control unit is approximately
10m.
see page 21
G
Is the remote control receiver connected and the remote control
being aimed at the projector?
G
Is the light-receiving area on the remote control blocked?
G
Has the remote control light-receiving area been subject to direct
sunlight, flourescent light or any other strong light source?
G
Have the batteries been mounted in place?
see page 21
G
Have the batteries run out?
G
Have the batteries been mounted back to front?
see page 21
G
Is the Operation Indicator illuminated in orange?
The projector has been designed so that the Operation Indicator is not
extinguished even when the power has been switched off.
The Operation Indicator will be extinguished when the Power Plug
has been disconnected from the socket.
G
The fan will not cease operations.
The cool-down process (to allow the projector lamp to cool down; the
operation indicator will blink in orange) will be performed after the
power has been switch off by pressing the [Power] button. The
operation indicator will be illuminated in orange when this has been
completed, so remove the power plug from the socket at this point.
*The amount of time required for the cool-down process will depend
on the external temperature.

Advertisement