3. Using a slotted screwdriver,
remove the black, plastic
cap on each side of
the motor (Fig. 20), and
carefully withdraw the
spring-loaded
brush
assemblies.
Keep brushes
clean and sliding freely in
their guide channels.
NOTE: To reinstall
the same
brushes,
make sure that
the brushes
go back in the
same way they came
out.
This will avoid the need for a
"run-in"
period.
4.
5.
Fig. 20
Plastic Cap
Insert new brush assemblies
into the guide channels with the carbon
part
going in first, being certain to fit the two metal "ears" into their slots in the
channel (Fig. 20).
Remember
to replace both end caps after inspecting
or servicing
brushes.
Tighten the caps snugly, but do not over-tighten.
Before use, the saw should be
allowed to "RUN IN" (run at no load without
a blade) for 5 minutes to seat the
new brushes properly.