MAINTENANCE
5. PUMP
ONLY QUALIFIED MAINTENANCE
PERSONNEL ARE TO PERFORM THE
FOLLOWING REPAIRS.

SOLUTION PUMP REPLACEMENT

1. Turn off all switches and unplug machine.
2. Tilt machine back so bottom is exposed.
3. Remove the 6 screws that fasten the frame
to the solution tank.
4. Remove the solution hoses from the fittings
on the pump.
5. Reverse process to install.
PUMP REPLACEMENT KITS
MOTOR ONLY 86290270
PUMP HEAD ONLY 86290280
4-4
CAM & BEARING KIT
86290330
PLUNGER & SEALS KIT
86290350
CMPS 86290230 02/22/07

6. REGULATING UNLOADER

ONLY QUALIFIED MAINTENANCE
PERSONNEL ARE TO PERFORM THE
FOLLOWING REPAIRS.
UNLOADER REPLACEMENT
1. Turn off all switches and unplug machine.
2. Tilt machine back so bottom is exposed.
3. Remove the 6 screws that fasten the frame
to the solution tank.
4. Remove the solution hoses from the fittings
on the pump.
5. Remove the unloader.
6. Reverse process to install.
VALVE & O-RINGS KIT
(BOTH SIDES)
86290340