Float Shut-Off; Strainer; Circuit Breakers - Windsor COMPASS CMPS 10070050 Operating Instructions Manual

Multi-functional cleaning machine for commercial use
Table of Contents

Advertisement

MAINTENANCE

1. FLOAT SHUT-OFF

The float shut-off is located inside the
recovery tank. The purpose of the float
shut-off is to notify the user that the
recovery tank is full. Remove daily and
clean any debris for maximum airflow.

2. STRAINER

The strainer is located on the lower right
side between the front and rear wheels.
The strainer protects the check valve and
pump from debris. If there is little or no
solution flow to the ground, check the
stainer for debris. Drain the solution tank
and clean the solution strainer. To remove
the strainer, turn the bottom part of the
strainer counterclockwise until the bottom is
separated. Clean out the debris from the
wire mesh and reassemble. Make sure the
o-ring gasket is in place when reassembled.
4-2

3. CIRCUIT BREAKERS

Circuit breakers interrupt the flow of power
in the event of an electrical overload. When
a circuit breaker is tripped, reset it by
pressing the exposed button. If a circuit
breaker continues to trip, the cause of the
electrical overload should be found and
corrected.
CMPS 86290230 02/22/07
6 Amp. Protects the pump
motor.
10 Amp. Protects the vacuum
motor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents