REPLACING RED ON-OFF SWITCH, YELLOW CYCLING LIGHT OR CIRCUIT BREAKER. (ALSO WHITE
"MELT ON" SWITCH AND MELT CYCLE CONTROL ASSEMBLY FOR MELT CYCLE OPERATION)
1. Remove thermostat control knob by grasping outer edge and pulling straight out, without twisting or turning.
2. Remove two screws at top of front panel. Pull top edge to open.
3. Disconnect leads to switch, light or circuit breaker, and remove the damaged component. Mark disconnected
leads to identify them.
4. Mount the new circuit breaker (or melt cycle control) with fasteners provided. The new switch, or light, is
snapped into place from the front of the panel.
5. Connect leads to corresponding terminals on new component. Check completed circuit against circuit
diagram on rear panel.
6. Reverse steps 1 and 2 to close front panel.
REPLACING MAGNETIC CONTACTOR, TERMINAL BLOCK, GROUND LUG OR AUXILIARY TERMINAL
BLOCK
1. Remove four screws securing rear panel to fryer. Let the rear panel fall down straight before pulling it out.
2. Disconnect leads to the damaged component.
3. Connect the leads to corresponding terminal on the new component.
4. Remove screws securing the damaged component to the mounting panel.
REPLACEMENT PARTS MEF24A ELECTRIC FRYER
"A" SCREW
DIAL SHAFT "B"
"A"
INCREASE
DECREASE
1/4 TURN
Fig. 1
– 9 –
PL-52688