Weight and physical dimensions
Table 14
lists physical properties for the SN6000 Fibre Channel Switch.
Table 14
Switch physical dimensions
Property
Height
Width
Depth
Weight
Electrical specifications
Table 15
lists electrical specifications for the SN6000 Fibre Channel Switch.
Table 15
Electrical specifications
Specification
Operating voltage
Power source loading (maximum)
Heat output (maximum)
Circuit protection
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for
which it was tested. The ranges specified in
operating and non-operating conditions.
Table 16
Environmental requirements
Condition
Temperature
Humidity
Altitude
Vibration (IEC 68-2-6)
Shock (IEC 68-2-7)
78
Value
1U or 43.2 mm (1.70 in)
432 mm (17 in)
500 mm (19.7 in)
Dual power supply: 8.16 kg (18 lbs.)
Single power supply: 6.8 kg (15 lbs.)
Description
100 to 240 VAC; 50 to 60 Hz
1 A at 120 VAC/0.5 A at 240 VAC
Dual power: 80 watts nominal; 90 watts typical maximum
Single power: 73 watts nominal; 83 watts typical maximum
Internally fused
Table 16
Acceptable range during operation
5° to 40°C (41° to 104°F)
10% to 90%, non-condensing
3,048 m (0 to 10,000 feet) above sea
level
5 to 500 Hz, 0.27g, 5 sweeps
3.5g, 3ms, half sine, 20 repetitions
identify the acceptable environment for both
Acceptable range during
non-operation
–20° to 70°C (–4° to 158°F)
10% to 95%, non-condensing
15,240 m (0 to 50,000 feet) above
sea level
2 to 200 Hz, 0.5g, 5 sweeps
50g, 4216 mmps, 13msec, 3 axis