Specification
EMC immunity
System architecture
ANSI protocol
Modes of operation
Maximum frame size
Port-to-port latency
Weight and physical dimensions
nl
Table 19
lists physical properties.
Table 19 8Gb SAN Switch physical dimensions
Dimension
Height
Width
Depth
Weight
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for which it was tested. The ranges specified in
operating and nonoperating conditions.
Table 20 Environmental requirements
Condition
Ambient
temperature
Humidity
Altitude
Shock
Vibration
Airflow
50
SAN Switch technical specifications
Description
•
IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge
•
IEC 61000-4-3 Severity Level 3 for Radiated Fields
•
IEC 61000-4-4 Severity Level 3 for Fast Transients
•
IEC 61000-4-5 Severity Level 3 for Surge Voltage
•
IEC 61000-4-6 Conducted Emissions
•
IEC 61000-4-1 1 Voltage Variations
•
EN 61000-4-12 Oscillatory Waves Immunity
•
EN 61000-3-2 Limits for Harmonic Current Emissions
•
EN 61000-3-3 JEIDA
Nonblocking shared-memory switch
FC-PH (FC Physical and Signalling Interface standard)
FC Class 2, Class 3, and Class F
21 12-byte
Less than 2 microseconds with no contention (destination
port is free)
Measurement
29.3 mm (1.15 in)
208 mm (8.19 in)
280 mm (1 1.02 in)
1.27 kg (2.8 lb)
Acceptable range during operation
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
5% to 90% relative humidity,
non-condensing
0 to 10,000 ft (3 km) above sea level
40 G, 2mS duration
0.5 G, 10–500 Hz
47 cubic ft/minute
Table 20
list the acceptable environment for both
Acceptable range during
non-operation
-40°C to 70°C with maximum rate of
change of 20 C /hr
50% to 80% relative humidity,
non-condensing
0 to 40,000 ft (12 km) above sea level
140 G, 2mS,
2.0 G, 5–500 Hz
None required