j. Click OK to enable the changes.
For more information about QuickTools, see the HP StorageWorks SN6000 Fibre Channel Switch
QuickTools Switch Management User Guide.
To configure an SNMP trap using the CLI:
a. Telnet to the IP address of the switch from a server that has LAN access to the switch, and login to
the switch.
b. To modify the SNMP configuration, open an admin session and enter the
set setup snmp trap CLI command. This will display the current configuration of SNMP trap
parameters, followed by queries to allow changes to these parameters. Enter changes as needed to
the trap enabled state, IP address, port number, severity, version, and community name.
The following example configures SNMP trap 1:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> set setup snmp trap 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Current Values:
Trap1Enabled
Trap1Address
Trap1Port
Trap1Severity
Trap1Version
Trap1Community
New Value (press ENTER to not specify value, 'q' to quit):
Trap1Enabled
Trap1Address
Trap1Port
Trap1Severity
Trap1Version
Trap1Community (string, max=32 chars)
Do you want to save and activate this snmp setup? (y/n): [n]
For more information about CLI commands, see the HP StorageWorks SN6000 Fibre Channel Switch
Command Line Interface Guide.
4.
Configure the switches in OSEM by adding each SN6000 Fibre Channel Switch as a Managed System
configured with System Type set to FC Switch and the IP address for the switch. For detailed instructions,
see the OSEM documentation available at the websites listed in
documentation for SIM, RSP, and
False
10.0.0.254
162
warning
2
public
(True / False)
(hostname, IPv4, or IPv6 Address) :10.20.30.40
(decimal value, 1-65535)
(select a severity level)
1=unknown
6=warning
2=emergency
7=notify
3=alert
8=info
4=critical
9=debug
5=error
10=mark
(1 / 2)
OSEM" (page 47).