Suction Assembly Removal
1. Remove the image transfer roller.
2. Remove the paper exit.
3. Remove the fuser.
4. Remove all connectors from HV1 (9 connectors).
5. Remove all connectors from PWB-F (1 connector).
6. Remove the high voltage unit frame (8 screws).
7. Remove the two screws of the suction assembly.
Repair Information 3-25