Setting The T1 Time-Out Time; Setting The T2 Time-Out Time - Kyocera FS-1128MFP Service Manual

Service manual
Hide thumbs Also See for FS-1128MFP:
Table of Contents

Advertisement

Maintenance
item No.
Setting communication time 2
U641
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Start
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
T0 TIME OUT
T1 TIME OUT
T2 TIME OUT
Ta TIME OUT
Tb1 TIME OUT
Tb2 TIME OUT
Tc TIME OUT
Td TIME OUT
Setting the T0 time-out time
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the destination unit,
a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the cursor left/right keys.
Description
T0 time-out time
2. Press the start key. The value is set.

Setting the T1 time-out time

Sets the time before receiving the correct signal after call reception. No change is necessary for this mainte-
nance item.
1. Change the setting using the cursor left/right keys.
Description
T1 time-out time
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.

Setting the T2 time-out time

The T2 time-out time decides the following.
From CFR signal output to image data reception
From image data reception to the next signal reception
In ECM, from RNR signal detection to the next signal reception
1. Change the setting using the cursor left/right keys.
Description
T2 time-out time
2. Press the start key. The value is set.
Description
Description
Sets the T0 time-out time.
Sets the T1 time-out time.
Sets the T2 time-out time.
Sets the Ta time-out time.
Sets the Tb1 time-out time.
Sets the Tb2 time-out time.
Sets the Tc time-out time.
Sets the Td time-out time.
Setting range
30 to 90 s
Setting range
30 to 90 s
Setting range
Initial setting
1 to 255
69
Initial setting
56
Initial setting
36
Change in value per step
100 ms
2JN
1-3-59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2820

Table of Contents