Download Print this page

Electric Diagram; Troubleshooting - NewAir ACP-1300H Owner's Manual

Portable

Advertisement

3. Operating Instructions
Air Exhaust Hose
The hot air exhaust conducts the hot, moist air produced by the unit away from
the space you are cooling. The window kit and exhaust hose can also be moved
from room to room with the unit. You can exhaust the ACP-1300H by following
one of the following two methods:
Exhaust the hot air through a window or sliding glass door (a window
1.
kit extension may be necessary). Open the window or sliding glass
door, install the window kit, and connect the exhaust hose.
2.
If an existing window or sliding glass door cannot be used, a custom
opening through a wall or ceiling can be cut out in order to facilitate
the exhaust hose.
Please Note:
The hot air must be exhausted in order for the unit to produce a cooling effect.
When the ACP-1300H is not in use, safely store away the exhaust hose in a
clean, dry place.

4. Troubleshooting

Troubleshooting Your ACP-1300H Portable Air Conditioner
Before investing in repairs, check to see if any of the following apply to you:
Problems
Possible Causes
There could be power trouble.
1.The power cord is not
plugged in.
2.The circuit breaker has
been tripped.
The unit doesn't work.
3.There is a problem with
the socket or outlet.
4.Either the power cord is
damaged, or the fuse
needs to be replaced.
Either the timer has been
activated or the temperature
The unit stops working on its own.
in the room is lower than the
set temperature.
1.The room temperature is
There is no cool air coming out
lower than the set temp-
of the unit when it is in cooling
erature.
mode.
2.The evaporator is frosted
over.
1.The evaporator is frosted
There is no cool air coming out of
over.
the unit when it is in dehumidifying
2.The unit is eliminating frost.
mode.
Error code E2 is displayed on the
The water tank is full.
control pane.l
Error code E4 is displayed on the
The coil pipe is damaged.
control panel.
1.The voltage is too high or
Error code E1 is displayed on the
too low.
control panel.
2.The unit is damaged.
Please Note:
Never service your ACP-1300H portable air conditioner by yourself.
If your unit needs to be repaired, please contact your NewAir dealer
or a professional repair center for assistance.
12
Suggested Solutions
1.Connect the power cord corre-
ctly.
2.Reset the circuit at the breaker
box.
3.Change the socket or outlet.
4.Take the unit to a qualified techn-
ician and have the fuse replaced
(fuse specification: 3A/250V).
Either turn the timer off or wait
for the room temperature to rise.
1.Wait for the room temperature
to rise to resume normal
operation.
2.Allow the evaporator to defrost
and normal operation will
resume.
Allow the evaporator to defrost
andnormal operation will resume.
Empty the water tank and restart
the unit.
Replace the coil pipe.
1.Restart the unit when the voltage
is normal.
2.Have the unit repaired by your
NewAir dealer or at a professional
repair center.
14
3. Operating Instructions
Exhaust Hose
1.The exhaust hose can extend
from 1.8 feet to 6.5 feet. The
shorter the hose , the better
the cooling effect .
The hose should be as straight
2.
as possible, as sharp or unnece
-ssary bends in the hose will prevent effective airflow.
This will subsequently result in overheating and possible
shut-down of the unit.
3.The length of the exhaust hose
should not be extended past 6.5 feet.
Replacement hoses are available for
purchase through your NewAir
vendor. We also recommend that
you use only certified NewAir re-
placement parts.

5. Electric Diagram

13
15

Advertisement

loading