Please read all instructions carefully before operating

1. Safety Instructions

Warning
Connect the ACP-1300H's plug into an
appropriate power outlet.
Make sure the air conditioner's ground
wire is connected.
Do not turn off the power supply by
pulling the power cord; use the On/
Off power button.
To avoid injury, keep fingers and foreign
objects out of the unit.
If you notice smoke or an odd odor coming
from the ACP-1300H, turn the unit off and
disconnect the power plug.
2
Contents
(1) Warning................................................................................... 2
(2) Precautions.............................................................................. 3
(3) Maintenance......................................... ................................... 4
(1) ACP-1300H Unit and Accessories............................................... 5
(2) Control Panel ........................................................................... 6
(3) Remote Control......................................................................... 7
(1) Operating the ACP-1300H for the First Time; Operating Modes;
and Thermostat.........................................................................8
(2) Setting the Timer....................................................................... 9
(3) Adjusting the Airflow...................................................................9
(4) Installing the Battery for the Remote Control...............................10
(5) Emptying the Auxiliary Water Tank.........................................11-12
(6) Setting up the Exhaust Hose.................................................13-14
4.
....................................................................... 1 5
5.
Electrical Diagram
.......................................................................... 16
6.
Electrical Specifications
................................................................ 17
1. Safety Instructions
Precautions
Leave the ACP-1300H in an upright position for at least two hours before operating.
The unit must be installed in accordance with national and local wiring regulations.
The ACP-1300H's supply cord requires a Y-type attachment. If the supply cord is
damaged, it must be replaced by the manufacturer, an authorized service agent, or a
qualified repair professional in order to avoid further damage, to prevent voiding the
warranty, and to avoid bodily injury.
Never operate the ACP-1300H in an area where flammable gasses or chemicals are
present.
To prevent electromagnetic interference, place the unit at least three feet away from
radios or televisions.
When connecting or disconnecting the power cord, hold the plug itself - never pull the
power cord.
When not using the unit for an extended period of time, disconnect the power cord and
drain any water from the auxiliary water tank.
When cleaning the ACP-1300H, do not spray liquid directly onto the unit. Moreover,
do not use harsh chemicals or cleansers to clean the unit. Instead, apply water or a
mild cleanser to a soft cloth and wipe the ACP-1300H clean.
The ACP-1300H is not intended to support heavy objects, be used as a step-stool, or
be shaken or bumped into. Keep this in mind when deciding where to place the unit.
If you choose to use the continuous drain function on the ACP-1300H, make sure the
condensate can drain off into an appropriate receptacle.
To ensure adequate air circulation, place the air conditioner at least four inches away
from walls and furnishings. Be aware of draperies or other items which may interfere
with the intake vents and cause restricted airflow.
Place the ACP-1300H on a level, flat surface. Do not operate the unit on an angle of
more than 4 inches.
1
3

Advertisement

loading

Summary of Contents for NewAir ACP-1300H

  • Page 1: Table Of Contents

    Contents 1.Safety Instructions (1) Warning................... 2 (2) Precautions................3 (3) Maintenance................4 ACP-1300H Portable Air Conditioner 2. Parts List Owner's Manual (1) ACP-1300H Unit and Accessories..........5 (2) Control Panel ................6 (3) Remote Control................. 7 3.Operating Instructions (1) Operating the ACP-1300H for the First Time; Operating Modes; and Thermostat.................8 (2) Setting the Timer...............
  • Page 2: Safety Instructions (1) Warning

    Remove the rear cover by pulling it forward. 12.Fan Speed MODE SPEED TIMER WIND WIND 13.Timer Oscillation Button1 Oscillation Button2 10 11 12 13 14 15 16 16.Temperature Adjustment Please Note: Not all controls will require adjustment, as some controls may be designed for other NewAir models.
  • Page 3: Operating Instructions

    3.Operating Instructions 3. Operating Instructions Setting the Timer Function: 1.When first plugging in the ACP-1300H, a tone indicating that the power is connected ON/OFF TEMP To set the timer function, press the "Timer" button and enter the time that will sound. After pressing the "On" button, MODE SPEED TIMER...
  • Page 4: Electric Diagram

    2.The unit is damaged. NewAir dealer or at a professional repair center. Please Note: Never service your ACP-1300H portable air conditioner by yourself. If your unit needs to be repaired, please contact your NewAir dealer or a professional repair center for assistance.
  • Page 5: Technical Specifications

    6. Technical Specifications ACP-1300H Model Number Cooling Capacity (Btu/h) 13000(MAX) Heating Capacity (Btu/h) 13000(MAX) 120(MAX) Dehumidifying(Pints/day) 120V/60Hz Power Supply Cooling 1250W/10.8A Power Dehumidifying 950W/8.2A Consumption Heating 1000W/8.7A Water Tank Capacity (Liters) Temperature Set Range 61 F-88 F Noise Level(dB) Unit Weight (Lb) Unit Dimensions (inches) 13.8X17.4X34.2 Refrigerant...