3. Operating Instructions
Air Exhaust Hose
The hot air exhaust conducts the hot, moist air produced by the unit away from
the space you are cooling. The window kit and exhaust hose can also be moved
from room to room with the unit. You can exhaust the ACP-1300H by following
one of the following two methods:
Exhaust the hot air through a window or sliding glass door (a window
1.
kit extension may be necessary). Open the window or sliding glass
door, install the window kit, and connect the exhaust hose.
If an existing window or sliding glass door cannot be used, a custom
2.
opening through a wall or ceiling can be cut out in order to facilitate
the exhaust hose.
Please Note:
The hot air must be exhausted in order for the unit to produce a cooling effect.
When the ACP-1300H is not in use, safely store away the exhaust hose in a
clean, dry place.
12

4. Troubleshooting

Troubleshooting Your ACP-1300H Portable Air Conditioner
Before investing in repairs, check to see if any of the following apply to you:
Suggested Solutions
Problems
Possible Causes
There could be power trouble.
1.The power cord is not
1.Connect the power cord corre-
plugged in.
ctly.
2.The circuit breaker has
2.Reset the circuit at the breaker
been tripped.
box.
3.There is a problem with
The unit doesn't work.
3.Change the socket or outlet.
the socket or outlet.
4.Take the unit to a qualified techn-
4.Either the power cord is
ician and have the fuse replaced
damaged, or the fuse
(fuse specification: 3A/250V).
needs to be replaced.
Either the timer has been
Either turn the timer off or wait
activated or the temperature
The unit stops working on its own.
in the room is lower than the
for the room temperature to rise.
set temperature.
1.Wait for the room temperature
1.The room temperature is
to rise to resume normal
There is no cool air coming out
lower than the set temp-
operation.
of the unit when it is in cooling
erature.
2.Allow the evaporator to defrost
mode.
2.The evaporator is frosted
and normal operation will
over.
resume.
1.The evaporator is frosted
Allow the evaporator to defrost
There is no cool air coming out of
over.
andnormal operation will resume.
the unit when it is in dehumidifying
2.The unit is eliminating frost.
mode.
Error code E2 is displayed on the
Empty the water tank and restart
The water tank is full.
control pane.l
the unit.
Error code E4 is displayed on the
Replace the coil pipe.
The coil pipe is damaged.
control panel.
1.Restart the unit when the voltage
1.The voltage is too high or
is normal.
Error code E1 is displayed on the
too low.
2.Have the unit repaired by your
control panel.
2.The unit is damaged.
NewAir dealer or at a professional
repair center.
Please Note:
Never service your ACP-1300H portable air conditioner by yourself.
If your unit needs to be repaired, please contact your NewAir dealer
or a professional repair center for assistance.
14
3. Operating Instructions
Exhaust Hose
1.The exhaust hose can extend
from 1.8 feet to 6.5 feet. The
shorter the hose , the better
the cooling effect .
The hose should be as straight
2.
as possible, as sharp or unnece
-ssary bends in the hose will prevent effective airflow.
This will subsequently result in overheating and possible
shut-down of the unit.
3.The length of the exhaust hose
should not be extended past 6.5 feet.
Replacement hoses are available for
purchase through your NewAir
vendor. We also recommend that
you use only certified NewAir re-
placement parts.
13