Download Print this page

NewAir ACP-1300E Owner's Manual

Air & water, inc. portable air conditioner owner's manual

Advertisement

ACP-1300E Portable Air Conditioner
Owner's Manual
Please read all instructions carefully before operating

1. Safety Instructions

Warning
Connect the ACP-1300E's plug into an
appropriate power outlet.
Make sure the air conditioner's ground
wire is connected.
Do not turn off the power supply by pulling
the power cord; use the On/Off power
button.
To avoid injury, keep fingers and foreign
objects out of the unit.
If you notice smoke or an odd odor coming
from the ACP-1300E, turn the unit off and
disconnect the power plug.
2
Contents
(1) Warning................................................................................... 2
(2) Precautions.............................................................................. 3
(3) Maintenance......................................... ................................... 4
(1) ACP-1300E Unit and Accessories............................................... 5
(2) Control Panel ........................................................................... 6
(3) Remote Control......................................................................... 7
(1) Operating the ACP-1300E for the First Time; Operating Modes;
and Thermostat.........................................................................8
(2) Setting the Timer....................................................................... 9
(3) Adjusting the Airflow...................................................................9
(4) Installing the Battery for the Remote Control...............................10
(5) Emptying the Auxiliary Water Tank.........................................11-12
(6) Setting up the Exhaust Hose.................................................13-14
4.
....................................................................... 1 5
5.
.......................................................................... 16
6.
Electrical Specifications
................................................................ 17
1. Safety Instructions
Precautions
Leave the ACP-1300E in an upright position for at least two hours before operating.
The unit must be installed in accordance with national and local wiring regulations.
The ACP-1300E's supply cord requires a Y-type attachment. If the supply cord is
damaged, it must be replaced by the manufacturer, an authorized service agent, or a
qualified repair professional in order to avoid further damage, to prevent voiding the
warranty, and to avoid bodily injury.
Never operate the ACP-1300E in an area where flammable gasses or chemicals are
present.
To prevent electromagnetic interference, place the unit at least three feet away from
radios or televisions.
When connecting or disconnecting the power cord, hold the plug itself - never pull the
power cord.
When not using the unit for an extended period of time, disconnect the power cord and
drain any water from the auxiliary water tank.
When cleaning the ACP-1300E, do not spray liquid directly onto the unit. Moreover,
do not use harsh chemicals or cleansers to clean the unit. Instead, apply water or a
mild cleanser to a soft cloth and wipe the ACP-1300E clean.
The ACP-1300E is not intended to support heavy objects, be used as a step-stool, or
be shaken or bumped into. Keep this in mind when deciding where to place the unit.
If you choose to use the continuous drain function on the ACP-1300E, make sure the
condensate can drain off into an appropriate receptacle.
To ensure adequate air circulation, place the air conditioner at least four inches away
from walls and furnishings. Be aware of draperies or other items which may interfere
with the intake vents and cause restricted airflow.
Place the ACP-1300E on a level, flat surface. Do not operate the unit on an angle of
more than 4 inches.
1
3

Advertisement

loading

Summary of Contents for NewAir ACP-1300E

  • Page 1: Table Of Contents

    Be aware of draperies or other items which may interfere with the intake vents and cause restricted airflow. Place the ACP-1300E on a level, flat surface. Do not operate the unit on an angle of more than 4 inches.
  • Page 2: Safety Instructions (1) Warning

    When removing the filter from the ACP-1300E, following these steps: 1.Gently lift up the air filter cover. 2.Grasp the air filter and separate it from the cover.
  • Page 3: Operating Instructions

    3. Operating Instructions Drainage When the ACP-1300E is in operation, the condensed water will be drained into the water tank. If the water tank is full, a buzzer will sound 20 times, and the VFD indicator will display an "E2" error warning. At that time, the unit will cease...
  • Page 4: Electric Diagram

    Please Note: The hot air must be exhausted in order for the unit to produce a cooling effect. When the ACP-1300E is not in use, safely store away the exhaust hose in a clean, dry place. 4. Troubleshooting...
  • Page 5: Technical Specifications

    Unit Dimensions (inches) Refrigerant Please Note: The cooling capacity of the unit may be affected by several factors such as the height of the ceiling, the quality of insulation, number of windows, etc. ACP-1300E 13000(MAX) 120(MAX) 120V/60Hz Cooling 1250W/10.8 A Dehumidifying 950W/ 8.2A...