Trouble Shooting Of Brake By Qualified Service Person Only - Craftsman 113.235140 Owner's Manual

12 inch compound miter saw
Table of Contents

Advertisement

Wiring Diagram
.
: .......
:........:::._.
.......
White
Field
__.
__,
Red
N,O_
Switch
Trouble
Shooting
of brake
by qualified
service
person
only.
1.. Check commutation
at no load,, If there is a heavy
sparking which follows the curvature of the commuta-
tor: replace the armature°
2..To continue trouble shooting, now unplug the power
cord.
3., Install service brushes, especially if delayed come-in of
brake has been noticed before failure°
4. Check brake circuit for continuity:
remove brush caps
and brushes.. Use ohmmeter to check continuity from
brass brush holder to brush holder.
If open, locate
exact place using ohmmeters, As indicated by test,
tighten connection or replace field assembly or replace
switch
5. After repair, check direction of blade rotation vs., guard
arrow,
27

Hide quick links:

Advertisement

Table of Contents
loading