To set Local Sense function:
1. Slide down tiont cover of controller below ON/OFF
button. See Fig. 4.
2. Press the SENSE button. The "House" symbol will ap-
pear on the display screen. See Fig. 12.
3. Place the remote control in desired location in room. Be
sure there is a direct line between the remote control and
the unit.
To Cancel Local Sense function
While in "Local Sense"
function, press the SENSE button. The "House" symbol will
disappear from the display screen and Local Sense function
will be canceled.
Fig. 10 -- Room Air Temperature
Indicator on
Remote Control Display
DELAYED START/STOP
This function will delay the
Start/Stop function in incTements of 1 hour. Delayed Start/Stop
can be pro_alnmed with the unit turned ON or OFF.
With the unit turned ON:
1. Slide down fi+ont cover of controller below ON/OFF
button. See Fig. 4.
2. Press the DELAY button. The clock will advance 1 hour
and the word "STOP" and number "3" will flash. See
Fg. 11.
3. Press the DELAY button once to advance the clock an ad-
ditional hour until desired delayed time is reached. Be
sure to point the remote control toward the unit while
pressing the DELAY button.
4. The word +'STOP" will stop flashing when the command
has been transmitted and received by the unit.
With the unit turned OFF:
1. Slide do,a_ front cover of controller below ON/OFF
button. See Fig. 4.
2. Press the DELAY button. The clock will advance 1 hour
and the word "START" and number "3" will flash. See
Fig. 11.
3. Press the DELAY button once to advance the clock an ad-
ditional hour until desired delayed time is reached. Be
sure to point the remote control toward the unit while
pressing the DELAY button.
4. The word "START" will stop flashing when the com-
mand has been transmitted and received by the unit.
Cancelin_ Delayed Start/Stop
To cancel the Delayed Start/
Stop function, fbllow the instructions in Canceling Specific
Start/Stop Time Period section.
NOTE: The Delay setting is stored in Time period 3.
LOCAL SENSE FUNCTION (2-Way Remote Control)
The local sense function allows the remote control to operate
by transmitting the room air temperature to the unit at regular
intervals f?om wherever the controller is located in the room.
The unit wilt then operate to make the air near the remote con-
trol reach the desired temperature.
JJ:+5
•+-+-o+ + @
o
°
DAILY
PROGRAMMING DISPLAY WITH UNIT ON
J:%
PROGRAMMING DISPLAY WITH UNIT OFF
Fig. 11 -- Delayed Start/Stop
Indicators
on
Remote Control Display
Jj:%
o
IJg++
MOOE
FAN
SWEEP
&
&
o
&
LOCAL
--
SENSE
INDICATOR
Fig. 12-
Local Sense Indicator on Remote
Control Display

Advertisement

loading

This manual is also suitable for:

40bnb018-03638bnb018-03640bne018-036