Table 3 Compute enclosure thermal and power status (continued)
Item
Power Subsystem Status
Power Mode
Present Power
Power Limit
NOTE:
If redundancy mode is set to AC Redundant, or Power Supply Redundant, and power
redundancy is lost, then you must either add additional power supplies or change the redundancy
mode setting in the Onboard Administrator to restore Power Subsystem status. See the Insight
Display for corrective steps.
NOTE:
The Power Limit is dependent on the enclosure power redundancy setting and the number
and location of the power supplies in the enclosure. If a Static Power Limit has been specified, the
Power Limit displays that limit.

Complex Information screen

The Complex Information screen has three tabs:
Status
Information
Complex Logs

Status tab

The Status tab provides the current operational status of the entire complex and the status of each
compute enclosure and IOX in the complex.
62
Complex Overview
Description
The overall power status of the enclosure. Possible values are Unknown, OK,
Degraded, or Critical Error.
A user setting to configure the enclosure dc power capacity and the input power
redundancy mode of the enclosure. See
for possible values.
The amount of watts being consumed by all devices in the enclosure.
The maximum amount of power available for consumption by the enclosure measured
in watts.