Cpu Status - HP Integrity Superdome 2 User Manual

Hp integrity superdome 2 onboard administrator user guide
Hide thumbs Also See for Integrity Superdome 2:
Table of Contents

Advertisement

Item
Device Location
Device Operational
Device Degraded
Device Informational
Firmware Mismatch
Device Mismatch
Duplicate IP Address
Device Indictment
Partner Device Link
Virtual Connect Configured

CPU Status

Item
Resource Path
Status
FRU Read Status
Indictment Status
DIMM Status: CPU Socket 0 or 1
Item
Resource Path
Status
Description
The server blade has been placed in the wrong slot in the enclosure according to the
current fan configuration. Possible values are OK or Incorrect location for proper device
cooling.
Device has failed; status was not requested by the Onboard Administrator. Possible
values are OK or Error.
Device has failed; status was requested by the Onboard Administrator. Possible values
are OK or Error.
Device has an error. Possible values are OK or an Informational message.
NOTE:
Not applicable for c-Class server blades.
The now configured partition firmware version does not match the now configured
complex firmware bundle version. Possible values are OK or Error.
NOTE:
Not applicable for c-Class server blades.
The now configured device firmware version does not match the now configured complex
firmware bundle version. Possible values are OK or Error.
NOTE:
Not applicable for c-Class server blades.
The device has a duplicate IP address. Possible values are OK or Error.
NOTE:
Not applicable for c-Class server blades.
Indicates if the device has been indicted by the Superdome 2 Analysis Engine. Possible
values are OK or Error with an informational message.
NOTE:
Not applicable for c-Class server blades.
Possible values are OK or Inappropriate device in adjacent bay. This information does
not display if the server blade is not partnered with a storage blade.
NOTE:
Not applicable for HP Integrity Superdome 2 server blades.
Possible values are Configured for Virtual Connect or Not configured for Virtual Connect.
When the server blade is Not configured for Virtual Connect an informational icon with
an Other status displays. Go to the Virtual Connect Manager to configure the server
blade profile.
NOTE:
Not applicable for HP Integrity Superdome 2 server blades.
Description
The resource path for the processor socket.
The overall status of the processor. Possible values are Unknown, OK, Degraded, or
Failed.
The status of the FRU data for the processor. Possible values are Unknown, OK,
Degraded or Failed.
The indictment status of the processor. Possible values are OK or Error with an
informational message.
Description
The resource path for the DIMM socket.
The overall status of the DIMM. Possible values are Unknown, OK, Degraded, or Failed.