Checking The Connection; Nms Related Ci Commands - ZyXEL Communications RS-1612 User Manual

Table of Contents

Advertisement

or
nms mask add <IP address> [mask] and press Enter.
Mask, as given in this command, is a 16-bit value. Each bit
corresponds to a modem slot. The most significant bit
corresponds to slot 16, while the least significant bit
corresponds to slot 1. If a value of 1 is used in the bit, the
corresponding slot can not be managed with NMS software. If
this value is omitted in the mask add command, the default
value is 0 allowing all modems to be managed. The value
entered must be in hexadecimal format either using one 16-bit
word or two bytes where the first byte corresponds with slot 9
to slot 16.
To delete a mask type: nms mask del <IP address> and press
Enter.
3. Then type: nms save to save your settings.

Checking the connection

To make sure the LAN connection is ready, use the Win95 ping
function to ping the rack controller. Or in CI, use ip ping <IP
address> to ping any machine.
To make sure ZyView can recognize the rack(s) in your network
refer to the chapter Rack Configuration Management in the
ZyView User's Manual.

NMS related CI commands

Use the commands below to configure your rack system.
LAN interface configuration:
Command
sys ether type <0|1|2>
sys ether save
Description
Sets Ethernet interface type:
0=UTP 1=BNC 2=AUI.
Saves Ethernet interface type.
15

Advertisement

Table of Contents
loading