5.5.2 Tone Settings
Description
Value Range
Default Value
CW_TONE1_FRQ
Value Format
Description
Value Range
Default Value
CW_TONE1_GAIN
Value Format
Description
Value Range
Default Value
CW_TONE1_RPT
Value Format
Description
Value Range
Default Value
CW_TONE1_TIMING
Value Format
Description
216
Administrator Guide
Specifies the pattern, in milliseconds, of the hold alarm using up to 10
whole numbers (on 1, off 1, on 2, off 2...) separated by commas.
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
120,14880
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of call waiting tone 1 using
2 whole numbers separated by a comma.
0, 200–2000 (0: No tone)
425
Integer
Specifies the gain, in decibels, of call waiting tone 1.
-24–6
0
Integer
Specifies whether call waiting tone 1 is repeated.
0–1
–
0: No Repeat
–
1: Repeat
1
Comma-separated Integer
Specifies the pattern, in milliseconds, of call waiting tone 1 using up to
10 whole numbers (on 1, off 1, on 2, off 2...) separated by commas.
Document Version
2012-06