5.5.2 Tone Settings
Value Range
Default Value

BELL_CORE_PATTERN1_TIMING

Value Format
Description
Value Range
Default Value

BELL_CORE_PATTERN2_TIMING

Value Format
Description
Value Range
Default Value

BELL_CORE_PATTERN3_TIMING

Value Format
Description
Value Range
Default Value
218
Administrator Guide
0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
500,190,190,190,2890
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 1, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
2000,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 2, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
800,400,800,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 3, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
400,200,400,200,800,4000