Restoring Factory Default Settings

Action
FUNC.
Press
,
needed.
FUNC.
Press
.
1
Press/hold
FUNC.
Press
. If setting is
correct, then skip next step.
To change country code, press
FUNC.
Press
.
Press
.
2
FUNC.
Press
.
1
Press
.
Press
.
STR
FUNC.
Press/hold
STOP
and
keys. Do not release
RESET
yet.
When your country code
appears in the display, release
all the keys.
Initialization is complete.
Note: After initializing the inverter, use the Powerup Test on
page 8 to get the motor running again.
1
or
2
as
until...
1
,
,
,
2
Display
– – –
b
"B" Group selected
0 0 1
b
First "B" Group parameter
0 8 5
b
Country code for
initialization selected
0 2
00 = Japan
01 = Europe
02 = USA
1
or
to set;
2
0 8 5
b
Country code for
initialization selected
0 8 4
b
Initialization function
selected
0 0
00 = disable initialization,
clear trip history only
0 1
01 = enable initialization
0 8 4
b
Initialization now enabled
to restore all defaults
0 8 4
b
First part of key sequence
E U
Default parameter country
code shown during initial-
U S A
ization
J P
0 0 1
d
Function code for output
frequency monitor shown
11
Function/Parameter
to store.
STR