Chapter3 Wiring, Connecting - Hitachi SJ-DN Instruction Manual

Devicenet option
Table of Contents

Advertisement

3.1 Connection for DeviceNet connector
SJ-DN has a Pluggable open connector (Male contacts), and a Network connector (Female contacts)
attached. The inverter and attach connector have a seal which is color coordinated to correspond to the
DeviceNet cable. Ensure the cable and contact are wired in the same color cable.
Phoenix contact co, Ltd.
Dimension
Wiring of DeviceNet
Communication connector
3.2 Communication cable for DeviceNet
Use the connector which conforms to DeviceNet specification or five conductor cable and also make sure
that cable, connector and Network distance conform to DeviceNet specification.
Baud rate(kbps)
125
250
500
Cable side connector (attached connector)
Maker
8.3
18.2
No.
1
2
3
4
5
Figure 3-1 Connector specification
Maximum Trunk line length(m)
(Or Maximum system length(m))
500
250
100
CHAPTER 3
MSTB 2.5/5ST-5.08 AU
Blue
Black
2.54
5.0
20.32
25.4
Signal
Type of signal
mark
V-
- (Minus) side of power supply
CAN_L
Communication data (Low)
Shield
CAN_H
Communication data (High)
V+
+ (Plus) side of power supply
Maximum length(m)
6
5
WIRING, CONNECTING
Type
White
Red
Color label
Dimension in mm
Shield
Drop line
Maximum total length(m)