Hitachi SJ-DN Instruction Manual page 30

Devicenet option
Table of Contents

Advertisement

APPENDIX PARAMETER OBJECT LISTS
Function
Jump Frequency 2 (Param109)
Jump Freq Width 2 (Param110)
Jump Frequency 3 (Param111)
Jump Freq Width 3 (Param112)
Accel Stop Freq (Param113)
Accel Stop Time (Param114)
PID Enable (Param115)
PID-P Gain (Param116)
PID-I Gain (Param117)
PID-D Gain (Param118)
PID Scale (Param119)
PID Feedback Sel (Param120)
AVR Selection (Param121)
MotorVoltage Sel (Param122)
OperationModeSel (Param123)
EnergySavingResp (Param124)
Accel Time 2 (Param125)
2nd Accel Time 2 (Param344)
3rd Accel Time 2 (Param378)
Decel Time 2 (Param126)
2nd Decel Time 2 (Param345)
3rd Decel Time 2 (Param379)
Accel/Decel2 Sel (Param127)
2nd Acc/Dec2 Sel (Param346)
Accel2 StartFreq (Param128)
2ndAcc2StartFreq (Param347)
Decel2 StartFreq (Param129)
2ndDec2StartFreq (Param348)
AccelPattern Sel (Param130)
DecelPattern Sel (Param131)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
(2) Extend Group A object Class ID=102
Function
OI StartFreq Set (Param132)
OI End Freq Set (Param133)
OI Start Rate (Param134)
OI End Rate (Param135)
OI StartMode Sel (Param136)
O2 StartFreq Set (Param137)
O2 End Freq Set (Param138)
O2 Start Rate (Param139)
O2 End Rate (Param140)
AccCurveSwelling (Param141)
DecCurveSwelling (Param142)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
Inst
Attr
Size
1
165
4
1
166
2
1
167
4
1
168
2
1
169
4
1
170
2
1
171
1
1
172
1
1
173
2
1
174
2
1
175
2
1
176
1
1
181
1
00(200)/01(215)/02(220)/03(230)/
04(240)/05(380)/06(400)/07(415)/
1
182
1
08(440)/09(460)/10(480)/11(575)/
00(Normal)/01(Energy saving)/
1
185
1
1
186
2
1
192
4
2
192
4
3
192
4
1
193
4
2
193
4
3
193
4
1
194
1
00(Terminal)/01(Frequency)
2
194
1
00(Terminal)/01(Frequency)
1
195
4
2
195
4
1
196
4
2
196
4
00(Straight line)/01(S Curve)/
1
197
1
02(U Curve)/03(Reverse U Curve)
00(Straight line)/01(S Curve)/
1
198
1
02(U Curve)/03(Reverse U Curve)
Code
H'0E
H'10
Inst
Attr
Size
1
101
4
1
102
4
1
103
1
1
104
1
1
105
1
00(Set Frequency)/01(0Hz)
1
111
4
1
112
4
1
113
1
1
114
1
1
131
1
1
132
1
Code
H'0E
H'10
26
Monitoring/Setting Range
0.00 to 400.00(Hz)
0.00 to 10.00(Hz)
0.00 to 400.00(Hz)
0.00 to 10.00(Hz)
0.00 to 400.00(Hz)
0.0 to 60.0(s)
00(Invalid)/01(Valid)
0.2 to 5
0.0 to 3600.0(s)
0.00 to 100.00(s)
0.01 to 99.99(%)
00(OI)/01(O)
00(ON)/01(OFF)/
02(OFF on decel)
12(600)
02(Fuzzy)
0.0 to 100.0(s)
0.01 to 3600.00(s)
0.01 to 3600.00(s)
0.01 to 3600.00(s)
0.01 to 3600.00(s)
0.01 to 3600.00(s)
0.01 to 3600.00(s)
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
Monitoring/Setting Range
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
0 to 100(%)
0 to 100(%)
-400.00 to 400.00(Hz)
-400.00 to 400.00(Hz)
-100 to 100(%)
-100 to 100(%)
01(small swelling) to
10(large swelling)
01(small swelling) to
10(large swelling)
Magnifi-
Access
Com-
cation
rule
mand
100
Get/Set
A065
100
Get/Set
A066
100
Get/Set
A067
100
Get/Set
A068
100
Get/Set
A069
10
Get/Set
A070
1
Get/Set
A071
1
Get/Set
A072
10
Get/Set
A073
100
Get/Set
A074
100
Get/Set
A075
1
Get/Set
A076
1
Get/Set
A081
1
Get/Set
A082
1
Get/Set
A085
10
Get/Set
A086
100
Get/Set
A092
100
Get/Set
A292
100
Get/Set
A392
100
Get/Set
A093
100
Get/Set
A293
100
Get/Set
A393
1
Get/Set
A094
1
Get/Set
A294
100
Get/Set
A095
100
Get/Set
A295
100
Get/Set
A096
100
Get/Set
A296
1
Get/Set
A097
1
Get/Set
A098
Magnifi-
Access
Com-
cation
rule
mand
100
Get/Set
A101
100
Get/Set
A102
1
Get/Set
A103
1
Get/Set
A104
1
Get/Set
A105
100
Get/Set
A111
100
Get/Set
A112
1
Get/Set
A113
1
Get/Set
A114
1
Get/Set
A131
1
Get/Set
A132

Advertisement

Table of Contents
loading

Table of Contents