Hitachi SJ-DN Instruction Manual page 32

Devicenet option
Table of Contents

Advertisement

APPENDIX PARAMETER OBJECT LISTS
Function
Freq CovertScale (Param185)
Stop Key enable (Param186)
FRS Cancel Sel (Param187)
BRD Using Rate (Param188)
Stop Mode Select (Param189)
CoolingFunContrl (Param190)
BRD Mode Select (Param191)
BRD ON Level (Param192)
Thermistor Sel (Param193)
ThermistorErrLvl (Param194)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
(4) Extend Group B object Class ID=104
Function
Free V/f Freq 1(Param195)
Free V/f Volt 1(Param196)
Free V/f Freq 2 (Param197)
Free V/f Volt 2 (Param198)
Free V/f Freq 3(Param199)
Free V/f Volt 3 (Param200)
Free V/f Freq 4(Param201)
Free V/f Volt 4 (Param202)
Free V/f Freq 5 (Param203)
Free V/f Volt 5 (Param204)
Free V/f Freq 6(Param205)
Free V/f Volt 6 (Param206)
Free V/f Freq 7 (Param207)
Free V/f Volt 7 (Param208)
BrakeControlMode (Param209)
Brake Start Wait (Param210)
Brake Accel Wait (Param211)
Brake Stop Wait (Param212)
BrakeConformWait (Param213)
Releasing Freq (Param214)
ReleasingCurrent (Param215)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
(5) Extend Group C object Class ID=105
Function
Digital Input 1 (Param216)
Digital Input 2 (Param217)
Digital Input 3 (Param218)
Inst
Attr
Size
1
186
2
1
187
1
1
188
1
00(0Hz start)/01(Synchronize start)
1
190
2
1
191
1
00(Deceleration)/01(Free run)
1
192
1
00 • iAlways ON)/01(ON During Run)
00(Invalid)/01(Invalid during stop)/
1
195
1
1
196
2
330 to 380(V)/660 to 760(V)
00(Invalid)/01(PTC Enable)/
1
198
1
1
199
2
Code
H'0E
H'10
Inst
Attr
Size
1
100
2
1
101
2
1
102
2
1
103
2
1
104
2
1
105
2
1
106
2
1
107
2
1
108
2
1
109
2
1
110
2
1
111
2
1
112
2
1
113
2
1
120
1
1
121
2
1
122
2
1
123
2
1
124
2
1
125
2
1
126
2
0 to 200(%) (constant current)
Code
H'0E
H'10
Inst
Attr
Size
01(RV)/02(CF1)/03(CF2)/04(CF3)/
05(CF4)/06(JG)/07(DB)/08(SET)/
13(USP)/14(CS)/15(SFT)/16(AT)/
1
101
1
28(DWN)/29(UDC)/31(OPE)/
32(SF1)/33(SF2)/34(SF3)/35(SF4)/
42(TRQ2)/43(PPI)/44(BOK)/
45(ORT)/46(LAC)/47(PCLR)/
1
102
1
1
103
1
28
Monitoring/Setting Range
0.1 to 99.9
00(Invalid)/01(Valid)
0.0 to 100.0(%)
02(Valid)
02(NTC Enable)
0 to 9999(Ħ)
Monitoring/Setting Range
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
0 to 400(Hz)
0.0 to 800.0(V)
00(Invalid)/01(Valid)
0.00 to 5.00(s)
0.00 to 5.00(s)
0.00 to 5.00(s)
0.00 to 5.00(s)
0.00 to 400.00(Hz)
Monitoring/Setting Range
09(2CH)/11(FRS)/12(EXT)/
17(SET3)/18(RS)/20(STA)/
21(STP)/22(F/R)/23(PID)/
24(PIDC)/26(CAS)/27(UP)/
36(SF5)/37(SF6)/38(SF7)/
39(OLR)/40(TL)/41(TRQ1)/
48(STAT)/255(NO)
Same above
Same above
Magnifi-
Access
Com
cation
rule
mand
10
Get/Set
b086
1
Get/Set
b087
1
Get/Set
b088
10
Get/Set
b090
1
Get/Set
b091
1
Get/Set
b092
1
Get/Set
b095
1
Get/Set
b096
1
Get/Set
b098
1
Get/Set
b099
Magnifi-
Access
Com-
cation
rule
mand
1
Get/Set
b100
10
Get/Set
b101
1
Get/Set
b102
10
Get/Set
b103
1
Get/Set
b104
10
Get/Set
b105
1
Get/Set
b106
10
Get/Set
b107
1
Get/Set
b108
10
Get/Set
b109
1
Get/Set
b110
10
Get/Set
b111
1
Get/Set
b112
10
Get/Set
b113
1
Get/Set
b120
100
Get/Set
b121
100
Get/Set
b122
100
Get/Set
b123
100
Get/Set
b124
100
Get/Set
b125
1
Get/Set
b126
Magnifi-
Access
Com
cation
rule
mand
1
Get/Set
C001
1
Get/Set
C002
1
Get/Set
C003

Advertisement

Table of Contents
loading

Table of Contents